Saturday 12 September 2015

IFM DD2003 Speed Monitor....!




Characteristic:

MONITOR
FR-1
Housing for DIN rail mounting
2 relay outputs
2 transistor outputs
Analog output
0/4...20 mA
programmable
Test function without external frequency
Key function

Application:
single pulse evaluation system with µprocessor for frequency; rotational speed; speed and machine cycles 

 
Switching function:
2 switch points for monitoring overspeed/underspeed and acceptable range


Wiring
1:  DC Supply voltage (L-)
2:  DC Supply voltage (L+)
3:  supply transistor outputs (L+)
4:  sensor signal pnp
5:  DC Sensor supply (L+)
6:  DC Sensor supply (L-)
7:  AC Supply voltage (L1)
8:  AC Supply voltage (N)
9:  n.c.
10:  sensor signal npn
11:  n.c.
12:  n.c.
13:  Relay 1 (common)
14:  Relay 1 (normally open)
15:  Relay 1 (normally closed)
16:  transistor output 1 pnp
17:  Reset 1 pnp
18:  Reset 2 pnp
19:  Relay 2 (common)
20:  Relay 2 (normally open)
21:  Relay 2 (normally closed)
22:  analog output (+)
23:  analog output (-)
24:  transistor output 2 pnp
  
    

Tuesday 8 September 2015

Transducer

transducer is a device that Converts one form of energy to another.
for example, a loudspeaker  converts an electric signal to sound),
 Mostly use in Industry  any  variable attennuation of energy may serve as input; for example, the light reflecting off the landscape, although it is not a signal, conveys information thatImage sensor , oneform of transducer, .









Sunday 6 September 2015

Digital Manometer Pressure Measurement Instrument

Digital Manometers

Digital Manometers
The 2000P Series of hand-held digital manometers are easy to operate, reliable and built to meet the performance and cost demands of today's industrial and HVAC professionals.

Representing a new standard in pressure measurement these digital manometers feature a number of innovative functions designed to make the operators job easier. Pressure ranges from Absolute up to10bar are available or 500bar using external transducers. All instruments are IP67 and have auto -ranging displays for precise readings.
  1. The PM range of digital manometers offer good performance,
  2.  using measurement technology developed from the 2000P series of digital manometers.
  3. Specifically designed for engineers using twin tube connections,
  4.  The PM range of digital manometers is ideal for soundness testing and setting up boiler differential gas pressures.
  5.  It can be magnetically attached for ease of use, and the back lit LCD allows easy viewing of the display in poor light conditions.
  6. Digital manometers are available with alternative pressure measurement units as factory set options or as a selectable option on the PM-80 which also incorporates a smoothing and min/max function.


Pressure Switch


How To Work Touch Screen


Friday 28 August 2015

Self Holding Circuit


4 & 20 mA Differentiate


Troubleshooting tips of profibus



Like This

https://www.facebook.com/World.Engineers.Quest.nawabshah


Load Cell

This product is suitable for low capacity platform scales, packaging machines, hybrid scales and process weighing.

Fully welded construction and water block cable-entry ensure that this product can be used successfully in harsh environments found in the food, chemical and allied industries.

Features:

• Fully welded, stainless steel construction
• Hermetically sealed, IP66 and IP68
• Certified to OIML R-60, 4000d
• ATEX certified versions are available for use in potentially explosive atmospheres
• Current calibration output (SC version) ensures easy and accurate parallel connection of multiple load cells
• Capacities: 5 to 500 kg





Parameter of Autonic Controller TZ4L/M







PT100 Connection with Autonic Controller TZ4L

















Thursday 27 August 2015

Dead Weight Tester

  1. dead weight tester apparatus uses known traceable weights to apply pressure to a fluid for checking the accuracy of readings from a pressure gauge
  2.  A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston.
  3. Typically deadweight testers are used in calibration laboratories to calibrate pressure transfer standards like electronic pressure measuring devices.

Pressure Tx: Calibration Fuji







Wednesday 26 August 2015

Pressure TX: Calibration (Siemens)

How to  Calibrate

Hold M(mode) for 2 to  4 second
again click mode to next setting (Total mode 14)

M5 mode is used for Inital set/zero scale (LDV)
M6 mode is used for span 100%            (UDV)
M7 used for zero adjustment if calibration is out 
(Zero adjust in atmosphere)

S.M


friend ur need Help

Friend please if you  visit my site then must follow , share and comment on post if u like my post Thanks 

2 , 3 wire proximity sensor connection

proximity sensor is a sensor able to detect the presence of nearby objects without any physical contact.Vibration measurements of rotating shafts in machinery.
  • Roller Coaster
  • Conveyor System
  • Mobile Devices
  • Touch Screen that come in close proximity to the face

     capacitive sensing is a technology, based on capacitive Coupling, that takes human body Capacitance as input. Capacitive sensors detect anything that is conductive or has a dielectric  different from that of air.

    Inductive
    An proximity(inductive) sensor is an electrinic Proximity sensor, which detects metallic objects without touching them



2, 3 and 4 wire RTD formula


Ohms to Degree Conversion

°C= Total Resistance-100*2.6°C= 109.625-100*2.6= 25.025°C


Degree convert into ohms

 ohms=  °C*.385 +100= 

 ohms=  25°C*.385+100=109.625ohms


linear variable differential transformer

The linear variable differential transformer (LVDT) (also called just a differential transformer,is a type of electrical transormer used for measuring linear displacement (position). A counterpart to this device that is used for measuring rotary displacement is called a rotary variable differential transformer (RVDT).
The linear variable differential transformer has three solenoid coils placed end-to-end around a tube. The center coil is the primary, and the two outer coils are the top and bottom secondaries. A cylindrical ferromagnetic core, attached to the object whose position is to be measured, slides along the axis of the tube. An  A.C drives the primary and causes a voltage to be induced in each secondary proportional to the length of the core linking to the secondary.The frequency is usually in the range 1 to 10 khz.








Tuesday 25 August 2015

Why cascade control loop is more preferable in the critical process , and what is an advantage of this loop ?


cascade uses in a criticle & precise controlling,it gives a 


predictive response where ever some possibility of d main 


feed/source disturbance,in this case cascade responds very 


quickly before any interruption in d process.

Monday 24 August 2015

how to convert Mv to Degree for j and k type thermocouple see

  1. for  J type Thermocouple= mv*18.85
for K type Thermocouple=mv*24.5

Example:
mv= 34
fot k type then =24.5*34= 833.c temp:
Thanks 

Sunday 23 August 2015

Aur wo cuteness #selfie wala Jin kha gya 😂😂


How to calibrate ultra sonic level transmitter? See

Ultrasonic transducers are transducers that convert ultrasound waves to electrical signals or vice versa. Those that both transmit and receive may also be called ultrasound transceivers; many ultrasound sensors besides being sensors are indeed transceivers because they can bothsense and transmit.


SOV Coil

A solenoid is simply an electromagnet
This is the basic working principles behind a solenoid but instead of picking up metal filings, the magnetism generated is used to move an armature which can do work.
In most appliance solenoids, instead of having a stationary pin (nail in the illustration above) around which the coil of wire is wrapped, the coil is wrapped around a hollow tube. Through the center of this tube a metal armature is installed which is affected by the magnet field produced whenever power is supplied to the coil. This armature can be attached to levers to lock or open a door for example and powered via an electrical switch when needed to activate it.



Magnetic Flow meter

The third most common flowmeter (behind differential pressure and positive displacement flow meters) is the magnetic flow meter, also technically an electromagnetic flow meter or more commonly just called a mag meter. A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. The physical principle at work is electromagnetic induction. The magnetic flow meter requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube.

actuator


optocoupler

  1. In electronics, an opto-isolator, also called anoptocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal.


Tajdar e HARAM


Schenck Process system Coal Feeding used in Cement Industry


  1. The Multicor-K small grained/powdery Coal Feeding System is specially designed for economical.
  2.  reliable and environmentally friendly powedry coal feeding for the firing of rotary kilns. 
  3. Using highly accurate Coriolis technology,
  4.  the Multicor-K system employs a matched Multicell unit,
  5.  which features a large inlet section and integrated agitator, providing the optimum solution for stable,
  6.  Equally material flow in the prebin.
  7.  Because the system is designed to eliminate aeration,
  8.  air pockets are minimized reducing the potential for pulsations or unstable conditions.


Schenck Process' superior coal dust feeding system offers economic kiln operation and high clinker quality based on stable temperatures and minimized excess air. The system is engineered to reduce fuel consumption, extend brick life and insure that SO2, NOx and CO do not exceed limit values.